ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2) ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
ABX Pentra 400 Chemistry Analyzer (2)
Horiba Medical

ABX Pentra 400 Chemistry Analyzer (2)

In stock. Enquire today

ABX Pentra 400 is an extremely compact Clinical Chemistry benchtop analyzer. Its great autonomy with continuous loading provides enhanced productivity in a user-friendly environment. From routine to specific tests, perform them all on a single system.

Specifications

Physical

System Size

40” x 28” x 25” (W x L x H)

System Weight

264 lbs

External Cooling Unit Size

12” x 17” x 16” (W x L x H)

External Cooling Unit Weight

77 lbs

Printer

Printer

Sound level

< 60 dBa

Operating temperature

from 15 to 32°C

Operating Humidity

from 20 to 85%

Total Power Requirements (with Printer)

1000 VA

Water

De-ionized/Distilled Water - 10L Tank

Water specifications

 

·        Resistivity > 5 MegOhms

·        Conductivity < 0.2 µS/cm

Computer & Sofware

Operating system

Windows XP

Data processing

·        12 inch Color LCD Touch Screen

·        Database Capacity: 100,000 results

·        Processor: 600 MHz

·        RC 232C: Patient results, QC to LIS with ASTM protocol

Integrated Validation Station

Quality Control Management

Levey Jennings, Automatic QC, Default controls and Westgard rules

Logs

·        Reagents, Quality Control, Calibrations

·        Applications, Maintenance, Sequencing, Flags and Alarms

Export of archived data and Quality Control data (QCP)

USB key

Audible alarms

Interactive Help

HTML Format

Optical System

Tungsten-halogen Lamp

Measurement Principle

·        Bi-chromatic light absorbance

·        Choice of 15 wavelengths from 340 to 700 nm

·        Wavelength selection with holographic grating technology

Sensor

Photo diode array

Optical Linearity

2.5 A. at 340mm; 3.0 at other wavelengths

 

See Leaflet Here

See University of Oxford Case Study Here